IBO Odontit - IBO Screw - M1.8 Hex. 1.25 self-locking — Prosthetic Screw compatible with ZIMMER SCREW VENT implant connection, platform NP, platform diameter 3.5mm, length 7.65mm. Reference HEI-35205. - # HEI-35205

IBO Odontit - IBO Screw - M1.8 Hex. 1.25 self-locking — Prosthetic Screw compatible with ZIMMER SCREW VENT implant connection, platform NP, platform diameter 3.5mm, length 7.65mm. Reference HEI-35205. - # HEI-35205
SKU: 495631 - ETD: Sold out - this item won't be restocked.
Quantity:

Minimum quantity is 1.

Manufacturer #
HEI-35205
Manufacturer
Model
ZIMMER®
SubModel
SCREW VENT
Sizes
3.5mm
Features
Screw
Features
Platform NP
Features
Titanium Grade 5
Package
1pk
Diameter
3.5
Length
7.65mm
ETD
Sold out - this item won't be restocked.
Talk to an expert!

Description

Hex drive prosthetic screwZIMMER screw VENT

the prosthetic screw is the smallest component in the assembly and the one most likely to be blamed when something goes wrong. This ZIMMER screw VENT screw measures 7.65mm in length and is machined to hold its preload through years of cyclic loading, which is the entire mechanism that keeps a restoration tight. Thread form, head geometry, and surface treatment are what determine whether the clamping force set at delivery is still there at the two-year recall.

Key Features

  • Thread geometry engineered to develop and hold preload at the specified torque
  • Grade 5 titanium alloy, with DLC or equivalent surface treatment on applicable references
  • Precision drive recess that resists cam-out and rounding during torquing
  • machined head seat that distributes clamping load evenly across the abutment
  • Manufactured to the original connection's dimensional specification
  • Overall length of 7.65mm matched to the corresponding prosthetic component

Key Selling Points

  • screw loosening is the most common late complication in implant prosthetics — This is where it is prevented
  • Low-friction surface treatment delivers more true clamping force from the same applied torque
  • Inexpensive enough to replace as a matter of routine at every abutment re-torque
  • Consistent drive geometry protects your torque drivers from premature wear
  • Stocking depth on a component that stops a case dead when it is missing

What Makes This Unique

Torque is not clamping force — friction consumes most of what is applied. the surface treatment on This screw reduces that friction loss, so more of the torque you apply becomes preload holding the joint together. That is the difference between a joint that stays closed under cyclic load and one that works loose.

How It Compares

Against reusing the original screw at re-torque, a fresh screw restores full preload; a used screw has already yielded slightly and never recovers its original clamping value. Against an untreated titanium screw, the coated version delivers measurably higher preload at identical applied torque. Against original-brand screws the thread and drive specifications are matched at a fraction of the cost on a genuinely consumable item.

Technical Specifications

Reference NumberHEI-35205
Product TypeHex drive prosthetic screw
Catalogue Designationscrew - M1.8 Hex. 1.25 self-locking
Compatible Implant SystemZIMMER
Implant Connectionscrew VENT
PlatformNP
Platform Diameter3.5mm
length7.65mm
MaterialTitanium alloy Grade 5 (Ti-6Al-4V ELI)
SterilityNon-sterile — steam-sterilize before clinical use
Country of OriginSpain
Sold As1pk

Compatibility

Engineered to interface with ZIMMER screw VENT, platform NP, platform diameter 3.5mm. Verify the platform designation and platform diameter of the placed implant against the specification table above before ordering. Where a surgical record is unavailable, a radiographic measurement or a trial fit with the corresponding analog is the reliable way to confirm the connection.

All implant system and connection names are the registered trademarks of their respective owners and are used here solely to identify prosthetic compatibility. This component is a third-party prosthetic part and is not manufactured, endorsed by, or affiliated with the owners of those marks.

What is in the Box

  • 1 x prosthetic screw
  • Reference and lot documentation

Handling & Care

Always use a calibrated torque driver at the implant manufacturer's stated value. Never re-use a screw for the definitive restoration after it has carried a provisional. Keep the drive recess clean and free of cement or bonding residue before engaging the driver.

Warranty

Covered against manufacturing and material defects. Contact manufacturer for full warranty terms and duration. Components that have been altered, re-machined, or used outside their stated indication fall outside warranty coverage.

Support

Technical guidance, compatibility confirmation, and documentation requests are handled through US Dental Depot. Reference number HEI-35205 when contacting support.

[Works with ZIMMER screw VENT — related searches: prosthetic screw, ZIMMER, screw VENT, dental implant prosthetics, implant compatible components, IBO HEI-35205, platform np, 3.5mm platform]