the prosthetic screw is the smallest component in the assembly and the one most likely to be blamed when something goes wrong. This DENTIUM BRIGHT screw is machined to hold its preload through years of cyclic loading, which is the entire mechanism that keeps a restoration tight. Thread form, head geometry, and surface treatment are what determine whether the clamping force set at delivery is still there at the two-year recall.
Torque is not clamping force — friction consumes most of what is applied. the surface treatment on This screw reduces that friction loss, so more of the torque you apply becomes preload holding the joint together. That is the difference between a joint that stays closed under cyclic load and one that works loose.
Against reusing the original screw at re-torque, a fresh screw restores full preload; a used screw has already yielded slightly and never recovers its original clamping value. Against an untreated titanium screw, the coated version delivers measurably higher preload at identical applied torque. Against original-brand screws the thread and drive specifications are matched at a fraction of the cost on a genuinely consumable item.
| Reference Number | IBO-4502-200 |
| Product Type | Hex drive prosthetic screw |
| Catalogue Designation | screw - M1.6 Hex 1.25 |
| Compatible Implant System | DENTIUM |
| Implant Connection | BRIGHT |
| Platform | RP |
| Material | Titanium alloy Grade 5 (Ti-6Al-4V ELI) |
| Sterility | Non-sterile — steam-sterilize before clinical use |
| Country of Origin | Spain |
| Sold As | 1pk |
Engineered to interface with DENTIUM BRIGHT, platform RP. Verify the platform designation and platform diameter of the placed implant against the specification table above before ordering. Where a surgical record is unavailable, a radiographic measurement or a trial fit with the corresponding analog is the reliable way to confirm the connection.
All implant system and connection names are the registered trademarks of their respective owners and are used here solely to identify prosthetic compatibility. This component is a third-party prosthetic part and is not manufactured, endorsed by, or affiliated with the owners of those marks.
Always use a calibrated torque driver at the implant manufacturer's stated value. Never re-use a screw for the definitive restoration after it has carried a provisional. Keep the drive recess clean and free of cement or bonding residue before engaging the driver.
Covered against manufacturing and material defects. Contact manufacturer for full warranty terms and duration. Components that have been altered, re-machined, or used outside their stated indication fall outside warranty coverage.
Technical guidance, compatibility confirmation, and documentation requests are handled through US Dental Depot. Reference number IBO-4502-200 when contacting support.
[Works with DENTIUM BRIGHT — related searches: prosthetic screw, DENTIUM, BRIGHT, dental implant prosthetics, implant compatible components, IBO IBO-4502-200, platform rp]
By submitting you agree to be contacted by US Dental Depot. We never share your details.