an impression coping's only job is to carry the implant's three-dimensional position out of the mouth without changing it. This ZIMMER SCREW VENT coping uses an Open-Tray technique, where the guide SCREW passes through the Tray and the coping stays in the impression on removal — the accepted approach when accuracy across multiple units matters most. the retentive geometry and the machined implant interface are what determine whether the master cast reproduces reality.
Everything downstream inherits This component's accuracy. A coping that rotates, seats incompletely, or releases from the impression material produces a cast that looks correct and is not — and that error is not discovered until the framework fails to seat.
Against a digital scanbody workflow, conventional impressions remain the more predictable route in deep, subgingival, or multi-unit situations where scanner line-of-sight is poor. Against a snap-fit polymer coping, a machined titanium interface holds its tolerance through repeated sterilization. Against original-brand copings the accuracy is equivalent at a materially lower cost on a reusable item.
| Reference Number | HEI-45700 |
| Product Type | Open Tray impression coping |
| Catalogue Designation | impression coping - Open Tray (OT) |
| Compatible Implant System | ZIMMER |
| Implant Connection | SCREW VENT |
| Platform | RP |
| Platform Diameter | 4.5mm |
| Material | Titanium alloy Grade 5 (Ti-6Al-4V ELI) |
| Sterility | Non-sterile — steam-sterilize before clinical use |
| Country of Origin | Spain |
| Sold As | 1pk |
Engineered to interface with ZIMMER SCREW VENT, platform RP, platform diameter 4.5mm. Verify the platform designation and platform diameter of the placed implant against the specification table above before ordering. where a surgical record is unavailable, a radiographic measurement or a trial fit with the corresponding analog is the reliable way to confirm the connection.
All implant system and connection names are the registered trademarks of their respective owners and are used here solely to identify prosthetic compatibility. This component is a third-party prosthetic part and is not manufactured, endorsed by, or affiliated with the owners of those marks.
Confirm complete seating radiographically before injecting impression material. On Open-Tray cases verify the guide SCREW is fully exposed through the Tray before the material sets. Inspect the interface for wear and steam-sterilize between patients.
Covered against manufacturing and material defects. Contact manufacturer for full warranty terms and duration. Components that have been altered, re-machined, or used outside their stated indication fall outside warranty coverage.
Technical guidance, compatibility confirmation, and documentation requests are handled through US Dental Depot. Reference number HEI-45700 when contacting support.
[Works with ZIMMER SCREW VENT — related searches: impression coping, ZIMMER, SCREW VENT, dental implant prosthetics, implant compatible components, IBO HEI-45700, platform rp, 4.5mm platform]
By submitting you agree to be contacted by US Dental Depot. We never share your details.