IBO Odontit - IBO Castable - Non-Engaging — Abutment compatible with NOBEL BIOCARE ACTIVE implant connection, platform NP, platform diameter 3.5mm, Non-Engaging, Castable. Reference HEC-35010. - # HEC-35010

IBO Odontit - IBO Castable - Non-Engaging — Abutment compatible with NOBEL BIOCARE ACTIVE implant connection, platform NP, platform diameter 3.5mm, Non-Engaging, Castable. Reference HEC-35010. - # HEC-35010
SKU: 494558 - ETD: Sold out - this item won't be restocked.
Quantity:

Minimum quantity is 1.

Manufacturer #
HEC-35010
Manufacturer
Model
NOBEL BIOCARE®
SubModel
ACTIVE®
Style
Non-Engaging, Castable
Sizes
3.5mm
Features
Abutment
Features
Castable
Features
Titanium Grade 5
Package
1pk
Diameter
3.5
ETD
Sold out - this item won't be restocked.
Talk to an expert!

Description

Castable abutmentNOBEL BIOCARE ACTIVE

This NOBEL BIOCARE ACTIVE abutment is The load-bearing link between The implant and The restoration, and its job is to transfer occlusal force into The fixture without ever letting The joint move. The Castable component allows a fully custom emergence profile to be waxed and cast to The individual site, giving The laboratory control that no stock geometry can offer, on a precision-machined metal base that preserves The implant interface.

Key Features

  • Precision-machined implant interface manufactured to The original connection specification
  • Grade 5 titanium alloy or cobalt-chromium base depending on The reference
  • Castable sleeve for a fully custom waxed and cast emergence profile
  • Anti-rotational indexing on engaging references for single-unit stability
  • Geometry designed to preserve The peri-implant soft-tissue seal

Key Selling Points

  • The component that determines margin position, emergence, and long-term tissue response
  • Full laboratory control of contour without giving up a machined implant interface
  • Supports both screw-retained and cement-retained restorative approaches
  • Substantial cost saving against original-brand components with matched connection geometry
  • Consistent machining across lots, which matters for multi-unit and repeat cases

What Makes This Unique

The abutment is where The biology and The mechanics meet. The connection has to be tight enough to resist micro-movement, and The emergence has to be shaped so The soft tissue forms a seal rather than a pocket. This component is machined to The original connection envelope so neither of those is a compromise.

How It Compares

Against a stock abutment with no height options, matching The gingival height to The site keeps The margin accessible and The tissue healthy. Against a fully custom milled abutment The cost is materially lower where The site does not demand bespoke contours. Against original-brand components The interface geometry is equivalent, and on multi-unit cases The difference changes The treatment's economics.

Technical Specifications

Reference NumberHEC-35010
Product TypeCastable abutment
Catalogue DesignationCastable - Non-Engaging
Compatible implant SystemNOBEL BIOCARE
implant ConnectionACTIVE
PlatformNP
Platform Diameter3.5mm
ConfigurationNon-Engaging, Castable
MaterialTitanium alloy Grade 5 (Ti-6Al-4V ELI)
SterilityNon-sterile — steam-sterilize before clinical use
Country of OriginSpain
Sold As1pk

Compatibility

Engineered to interface with NOBEL BIOCARE ACTIVE, platform NP, platform diameter 3.5mm. Verify The platform designation and platform diameter of The placed implant against The specification table above before ordering. Where a surgical record is unavailable, a radiographic measurement or a trial fit with The corresponding analog is The reliable way to confirm The connection.

All implant system and connection names are The registered trademarks of their respective owners and are used here solely to identify prosthetic compatibility. This component is a third-party prosthetic part and is not manufactured, endorsed by, or affiliated with The owners of those marks.

What is In The Box

  • 1 x abutment
  • 1 x abutment screw (where supplied with The component)
  • Reference and lot documentation

Handling & Care

Torque to The implant manufacturer's specification with a calibrated driver. Where The restoration is cement-retained, keep The margin accessible and remove every trace of excess cement. Steam-sterilize before intraoral use and do not modify The implant-mating surface.

Warranty

Covered against manufacturing and material defects. Contact manufacturer for full warranty terms and duration. Components that have been altered, re-machined, or used outside their stated indication fall outside warranty coverage.

Support

Technical guidance, compatibility confirmation, and documentation requests are handled through US Dental Depot. Reference number HEC-35010 when contacting support.

[Works with NOBEL BIOCARE ACTIVE — related searches: abutment, NOBEL BIOCARE, ACTIVE, dental implant prosthetics, implant compatible components, IBO HEC-35010, platform np, 3.5mm platform]

Related Products